  technical data january, 2011, rev. 0 1 5- v low - drop voltage regulator ile 4260 is a 5 - v low - drop fixed - voltage regulator in p - to220 - 5 package. the maximum input voltage is 42 v (65 v 400 ms). the device can produce an output current of more than 500 ma. it is shortcircuit - proof and incorporates temperature protection that disables the circuit at unpermissibly high temperatures. due to the wide temperature range of ? 40 to 150 c, the ile 4260 is also suitable for use in automotive applications. the ic regulates an input voltage v i in the range 6 < v i < 35 v to v q nominal =5.0 v. a reset signal is generated for an output voltage of v q < 4.75 v. the reset delay can be set externally with a capacitor. if the output current is reduced below 10 ma, the regulator switches internally t o standby and the reset generator is turned off. the standby current drops to max. 700 a. features ? low - drop voltage ? very low quiescent current ? low starting current consumption ? integrated temperature protection ? protection against reverse po larity ? input voltage up to 42 v ? overvoltage protection up to 65 v ( 400 ms) ? short - circuit proof ? suited for automotive electronics ? wide temperature range il e42 60- 2 ile4260s - 2 ile4260 - 2 i l e 42 60s - 2 p - t o220 - 5 - 2 i l e 42 60 - 2 p - t o220 - 5 - 1 t a = - 40 125 c for all packages
ile42 6 0 -2 january, 2011, rev. 0 1 pin configuration (top view) pin definitions and functions (ile 4260 and ile 4260 s) pin no. symbol function 1 v i input ; block directly to ground at th e ic by a 470 - nf capacitor 2 qvres reset output ; open collector output controlled by the reset delay 3 gnd ground 4 dres reset delay ; wired to ground with a capacitor 5 v q 5 - v output voltage ; block to ground with a 22 - f capacitor
ile42 6 0 -2 january, 2011, rev. 0 1 ci rcuit description the control amplifier compares a reference voltage, which is kept highly accurate by resistance adjustment, to a voltage that is proportional to the output voltage and drives the base of the series transistor via a buffer. saturation con trol as a function of the load current prevents any over - saturation of the power element. if the output voltage goes below 96% of its typical value, an external capacitor is discharged on pin 4 by the reset generator. if the voltage on the capacitor reache s the lower threshold v st , a reset signal is issued on pin 2 and not cancelled again until the upper threshold v dt is exceeded. for an output current of less than i qn off = 10 ma the standby changeover turns off the reset generator. the latter is turned on again when the output current increases, the output voltage drops below 4.2 v or the delay capacitor is discharged by external measures. the ic also incorporates a number of internal circuits for protection against: ? overload ? overvoltage ? overtemper ature ? reverse polarity block d iagram
ile42 6 0 -2 january, 2011, rev. 0 1 absolute maximum ratings parameter symbol limit values unit remarks min max input (pin 1) input voltage v i v i ? 42 ? 42 65 v v ? t 400 ms input current i i ? 1.6 a ? reset output (pin 2) voltage v r ? 0.3 42 v ? current i r ? ? ? internally limite d ground (pin 3) current i gnd ? 0.5 ? a ? reset delay (pin 4) voltage v d ? 0.3 42 v ? current i d ? ? ? internally limited output (pin 5) differential voltage v i ? v q ? 5.25 v i v ? current i q ? 1.4 a ? temperature storage temperature t stg ? 50 150 c ? operating range input voltage v i ? 32 v 1) junction temperature t j ? 40 165 c ? thermal resistances junction ambient r thja ? 65 k/w ? junction case r thjc ? 3 k/w ? 1) see diagram ?output current versus input voltage? * stresses beyond those listed under ?absolute maximum ratings? may cause per manent damage to the device. these are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under ?recommended operating conditions? is not implied. exposure to absolute - maximum - rated conditio ns for extended periods may affect device reliability.
ile42 6 0 -2 january, 2011, rev. 0 1 characteristics v i = 13.5 v; t j = 25 c; (unless otherwise specified) pa rameter symbol limit values unit test condition min. typ. max. normal operation output voltage v q 4.75 5.0 5.25 v 25 ma q 500 ma 6 v i 28 v ? 40 c j 125 c short - circuit current i sc 500 1000 ? ma v i =17 v to 28 v; v q = 0 v current consumption i q = i i ? i q i q ? 8.5 10 ma 1) 6 v i 28 v i q = 150 ma current consumption i q = i i ? i q i q ? 50 65 ma 1) 6 v i 28 v i q = 500 ma current consumption i q = i i ? i q i q ? ? 80 ma 1) v i 6 v i q = 500 ma drop voltage v dr ? 0.35 0.5 v v i = 4.5 v; i q = 0.5 a drop voltage v dr ? 0.2 0.3 v v i = 4.5 v; i q = 0.15 a load regulation ? q ? 15 35 mv 25ma q 500 ma supply - voltage regulation ? q ? 15 50 mv v i 6 v to 28 v; i q = 100 ma supply - voltage regulation ? q ? 5 25 mv v i 6 v to 16 v; i q = 100 ma ripple rejection svr ? 54 ? db f = 100 hz; v r = 0.5 v pp temperature drift of output voltage 1) vq ? 2 10 ?4 ? 1/c ? stan dby operation quiscent current; i q = i i ? i q i q ? 500 700 a 10v i 16 v; i q = 0ma quiscent current; i q = i i ? i q i q ? 750 850 a 10v i 16 v; i q = 5ma
ile42 6 0 -2 january, 2011, rev. 0 1 characteristics (cont?d) v i = 13.5 v; t j = 25 c; (unless otherwise sp ecified) parameter symbol limit values unit test condition min. typ. max. standby off/normal on current consumption i qsoff ? 1.0 1.2 ma see test diagram current consumption i qnon ? 1.7 2.2 ma see test diagram normal off/standb y on current consumption i qnoff ? 1.55 2.00 ma see test diagram current consumption i qson ? 850 1050 a see test diagram switching threshold i qnoff 7.5 10 12.5 ma see test diagram switching hysteresis ? q 2.25 3 4 ma see test diagram reset generator switching threshold v rt 94 96 97 % in % of v q ; i q > 500ma; v i = 6 v saturation voltage v r ? 0.25 0.40 v i r = 3 ma; v i = 4.5 v reverse current i r ? ? 1 a v r = 5 v charg e current i d 7 10 13 a ? switching threshold v st 0.9 1.1 1.3 v ? delay switching threshold v dt 2.15 2.50 2.75 v ? delay time t d ? 25 ? ms c d = 100 nf delay time t t ? 5 ? s c d = 100 nf general data turn - off voltag e v ioff 40 43 45 v i q < 1 ma turn - off hysteresis ? i ? 3.0 ? v ? leakage current i qs ? 500 ? a v q = 0 v; v i = 45 v reverse output current i qr ? ? 1.5 ma v q = 5 v; v i = open 1) see diagram
ile42 6 0 -2 january, 2011, rev. 0 1 application circuit time responce
ile42 6 0 -2 january, 2011, rev. 0 1 time response in standby condition
ile42 6 0 -2 january, 2011, rev. 0 1 p a c kage d imension s p - to220 - 5 - 2 p - to220 - 5 - 1


▲Up To Search▲   

 
Price & Availability of ILE4260S-2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X